Abstract

Peri- and post-procedural ventricular tachycardia (VT) is a rare complication after leadless pacemaker implantation and requires an individualized approach. In this case report we describe the management of VT in a patient with subendocardial scarring due to prior coronary artery disease who presented with monomorphic VT the day after implant. The etiology was found to be related to the novel ventricular activation wavefront by ventricular pacing which induced a reentrant circuit dependent on pre-existing myocardial substrate. Invasive electrophysiologic study and ablation is a safe and successful treatment strategy in selected patients with evidence of myocardial scarring.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.