Abstract

AbstractPressure relief venting of a runway reaction with gas generation is examined in terms of the overall system response and the associated venting requirement. This article presents an exact formulation as well as an approximate analytical approach. The latter is shown to be particularly useful in vent‐sizing applications. Using an aqueous hydrogen peroxide decomposition example, the analytical results are demonstrated to agree well with the exact numerical results over a wide range of overpressure. In addition, the analytical result is shown to reduce to the correct limit for a pure vapor system and offers a useful vent‐sizing equation for a pure‐gassy system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.