Abstract

Abstract The utilization of a venting strategy to remove gasoline vapors from contaminated soil strata was investigated in this exper‐ment. A contained gasoline “leak”; was created in a large outdoor facility which simulated soil strata and a static water table. An air flow was established, and vapor samples taken before, during, and after venting were checked for hydrocarbon content. The effluent air was regularly sampled for carbon dioxide and total hydrocarbons. Carbon dioxide data were used to estimate the amount of microbiological activity, and total hydrocarbon data were used to calculate the total amount of gasoline removed by venting. Hydrocarbon condensates from the effluent air were collected periodically and the compositions of these condensates were compared to the compositions of the starting gasoline and the residual that remained in the soil. During 11 days of continuous venting, 57% of the original 75 gallons of gasoline was removed by venting. Carbon dioxide production indicates that micr...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.