Abstract

Ventilation-perfusion (V/Q) scan coupled with single photon emission computed tomography (SPECT) is commonly used for the diagnosis of pulmonary embolism (PE). An abnormal chest x-ray (CXR) is deemed to hinder the interpretation of V/Q scan and therefore a normal CXR is recommended prior to V/Q scan. To determine if an abnormal CXR impacted on V/Q scan interpretation and subsequent management. A retrospective cohort analysis of all patients who underwent a V/Q scan for diagnosis of suspected acute PE between March 2016 and 2022 was performed. CXR reports were reviewed and classified as normal or abnormal. Low-dose computerised tomography was routinely performed in patients above the age of 70. Data regarding V/Q scan results and subsequent management including initiation of anticoagulation for PE or further diagnostic investigations were collected. A total of 340 cases were evaluated. Of the positive V/Q scans (92/340), 98.3% of the normal CXR were anticoagulated compared to 100% of the abnormal CXR group. Of the negative V/Q scans (239/340), no cases were started on anticoagulation and no further investigations were performed across both normal and abnormal CXR groups. Indeterminate results occurred in only 9 cases with no significant difference in management between normal and abnormal CXR groups. An abnormal CXR does not affect the reliability of V/Q scan interpretation in the diagnosis of PE when coupled with SPECT. Unless clinically indicated, the mandate by clinical society guidelines for a normal CXR prior to V/Q should be revisited.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call