Abstract
Computational fluid dynamics (CFD) method is implemented to investigate the flow and heat transfer within the radial forced air-cooled fractional-slot concentrated-winding (FSCW) permanent magnet generator for decreasing ventilation loss and temperature rise. Firstly, a CFD model is established and the losses and boundary conditions are determined. Secondly, the fluid and temperature field of machines with different channel numbers and channel widths are calculated, and the ventilation and thermal performance are compared. Finally, an alternative cooling structure with radial winding holes through the slot center to dissipate heat from the winding directly, especially for the FSCW permanent magnet generators, is proposed in this paper. The results show that it is a promising alternate for decreasing the winding temperature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.