Abstract

A 48-year-old man presented with symptomatic inferior vena cava (IVC) occlusion from a chronically thrombosed and embedded Vena Tech LGM filter resulting in exercise intolerance from diminished cardiac preload and postthrombotic syndrome from chronic venous insufficiency. The patient was treated using a new PRIME technique—Piecemeal Removal by Intentional MEchanical fracture—to achieve successful filter retrieval 16 years after implantation. Removal of the obstructing filter permitted endovascular IVC recanalization with restoration of venous outflow and alleviation of venous obstructive symptoms. Cardiac preload was restored, allowing the patient to resume long-distance running, and he successfully completed a half-marathon 3 months after treatment.