Abstract

BACKGROUND. Intestinal inflammation is associated with radiologic and histologic hyperemia. A paucity of studies have used MRI to measure mesenteric blood flow in patients with Crohn disease. OBJECTIVE. The purpose of this study was to evaluate the application of velocity-encoded phase-contrast MRI for measuring mesenteric blood flow in patients with newly diagnosed small-bowel Crohn disease. METHODS. This prospective study included 20 patients with ileal Crohn disease newly diagnosed between December 2018 and October 2021 (eight female participants, 12 male participants; median age, 14.0 years), and 15 healthy control participants (eight female participants, seven male participants; median age, 17.0 years). Patients with Crohn disease underwent investigational MRI and laboratory assessments at diagnosis and at 6 weeks and 6 months after initiating anti-tumor necrosis factor-α medical therapy; control participants underwent a single investigational MRI examination. All MRI examinations included a velocity-encoded phase-contrast acquisition, which was used to measure blood flow in the abdominal aorta, superior mesenteric artery (SMA), and superior mesenteric vein (SMV). Mann-Whitney U test was used to compare blood flow measurements (ratios of SMA and SMV blood flow to aorta blood flow [hereafter, SMA-to-aorta and SMV-to-aorta blood flow, respectively]) between groups; Friedman test was used to evaluate temporal changes in blood flow. Spearman correlation was used to assess relationships between blood flow measurements and laboratory markers of intestinal inflammation. Diagnostic performance was assessed by ROC analysis. RESULTS. At baseline, SMA-to-aorta blood flow in patients versus control participants was 0.44 versus 0.30 (p = .003), and SMV-to-aorta blood flow was 0.36 versus 0.21 (p = .002). At 6 weeks and 6 months, SMA-to-aorta blood flow in patients decreased to 0.30 and 0.27 (p < .001), and SMV-to-aorta blood flow decreased to 0.27 and 0.21 (p = .02), respectively. SMA-to-aorta and SMV-to-aorta blood flow were positively correlated with C-reactive protein (rho, 0.34 [p = .01] and 0.35 [p = .008], respectively) and fecal calprotectin (rho, 0.34 [p = .01] vs 0.47 [p < .001]). AUCs for differentiating patients from controls were 0.79 for SMA-to-aorta (sensitivity, 60%; specificity, 100%) and 0.82 for SMV-to-aorta (sensitivity, 75%; specificity, 87%) blood flow. CONCLUSION. Mesenteric blood flow is quantifiable using velocity-encoded phase-contrast MRI. The measurements differ between patients with ileal Crohn disease and healthy control participants and change in response to medical therapy. CLINICAL IMPACT. MRI-based mesenteric blood flow measurements provide a potential novel marker of intestinal inflammation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call