The phase velocity and the backscatter coefficient were measured in 28 bovine femoral trabecular bone samples filled with marrow and water in vitro from 0.2 to 0.6 MHz. The phase velocities decreased approximately linearly with increasing frequency and the average dispersion rate of -34 ms-1 MHz-1 in the marrow-filled samples was higher than that of -42 ms-1 MHz-1 in the water-filled samples. The backscatter coefficients exhibited nonlinear, monotonically increasing dependences on the frequency and the average value of the exponent n = 2.92 (frequency dependence) in the marrow-filled samples was higher than the value of n = 2.79 in the water-filled samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.