Abstract

Although arteries appear to remodel in response to changes in hemodynamic parameters such as shear stress, little is known about functioning human vein grafts. This study was designed to explore diameter changes in human saphenous vein grafts after infrainguinal bypass. We used duplex ultrasonography to measure hemodynamic variables that might affect the diameter of 48 in situ saphenous vein grafts during the first year after infrainguinal arterial bypass. Volumetric flow rate, average velocity, peak systolic velocity, and vein diameter in the proximal and distal thirds of these grafts were each measured at 1 week and at 3, 6, and 12 months after operation. Veins were divided into three groups based on initial size (1 week after bypass) in the below-knee segment: small, < 3.5 mm diameter; medium, 3.5 to 4 mm diameter; and large, > 4 mm diameter. Distal vein diameters at 1 week for small, medium, and large grafts were 2.9 +/- 0.1, 3.7 +/- 0.1, and 4.3 +/- 0.1 mm, respectively (p < 0.001), but by 12 months these diameters were 3.6 +/- 0.2, 3.8 +/- 0.2, and 3.9 +/- 0.2 mm, respectively (p = 0.54). Large veins decreased in diameter, whereas small veins increased in diameter, as confirmed by linear regression of percent change in diameter versus initial vein graft diameter (r = -0.62, p < 0.001). Volumetric flow rate, peak systolic velocity, and shear stress also tended to approach uniform values over time. Of the hemodynamic variables studied, the best predictor of diameter change was shear stress (linear regression of percent change in diameter vs shear stress, r = 0.67, p < 0.001). Veins with a diameter increase greater than 10% over time had significantly higher initial shear stress than veins with a diameter decrease greater than 10% over time (28.6 +/- 3.8 vs 13.1 +/- 1.8 dynes/cm2, p < 0.01), whereas initial volumetric flow rates in these two groups were similar (135 +/- 23 vs 130 +/- 15 ml/min). Infrainguinal in situ vein graft diameter, volume flow rate, peak systolic velocity, and shear stress all tend to stabilize at uniform values regardless of the initial vein graft diameter. Of the hemodynamic variables studied, shear stress is most strongly associated with the change in diameter over time. Thus human saphenous vein appears to be capable of adapting to its hemodynamic environment after arterial grafting by modulating diameter to normalize shear stress.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.