Abstract

Introduction In men with ≥pT1G2 cN0, penile cancer lymph node sampling is recommended with either (1) scintigraphically labelled Dynamic sentinel lymph node biopsy (DSLNB) or (2) modified inguinal lymph node dissection (MILND). Although DSLNB is a minimally invasive technique, the false negative rate can be about 10%, and a further operative procedure is required if positive. Open MILND is a diagnostic and therapeutic option but has a much higher morbidity. A potential compromise is the technique of LND-VEILND (video endoscopic inguinal LND) that can be combined with ICG florescence marking of sentinel lymph node (SLN). We present a pilot study of ICG-VEILND. The aim was to validate the applicability of a combination ICG marking of SLN in VEILND (to increase probability to excise SLN) and determine the optimal timing and dosage of ICG. Materials and Methods 15 patients with VEILND (24 groins) underwent ICG application with fluorescence near-infrared (NIR 803⟶830 nm) detection. ICG is applied subcutaneously adjacent to the penile cancer or residual stump of penis or suprapubic region (in a history of total penectomy: 5 cases). The dose of 1.25 mg (ICG) was applied in one case with invisible SLN, the dose of 2.5 mg in 1 mL in 8 cases, and 5 mg in the remaining 6 patients (10 groins). Results Failure of marking SLN with ICG occurred in 25.0% of cases (6/24): due to application of 1.25 mg ICG, extensive metastasis to SLN, in 4 cases, the cause was unknown (16.7%, 4/24). In the short follow-up period, no local recurrence was seen in the pN0 ICG group. Conclusion Fluorescence infrared image with ICG dye increases the probability of removal of the SLN during VEILND. The dose of ICG is 2.5 (5) mg diluted in 1 ml and can be applied preoperatively even in the suprapubic region in men with a history of total penectomy, with an unexplainable failure of ICG marking in 16.7%.

Highlights

  • In men with ≥pT1G2 cN0, penile cancer lymph node sampling is recommended with either (1) scintigraphically labelled Dynamic sentinel lymph node biopsy (DSLNB) or (2) modified inguinal lymph node dissection (MILND)

  • VEILND was performed in 33 groins (20 men), with indocyanine green (ICG) in 15/24 (See Table 1 for details). e great saphenous vein was not preserved in 4 groins (12.1%)

  • A single positive LN was detected in 7 groins, two positive LNs were noted in 1 groin and four positive LNs in the remaining groin

Read more

Summary

Introduction

In men with ≥pT1G2 cN0, penile cancer lymph node sampling is recommended with either (1) scintigraphically labelled Dynamic sentinel lymph node biopsy (DSLNB) or (2) modified inguinal lymph node dissection (MILND). A potential compromise is the technique of LND-VEILND (video endoscopic inguinal LND) that can be combined with ICG florescence marking of sentinel lymph node (SLN). 15 patients with VEILND (24 groins) underwent ICG application with fluorescence near-infrared (NIR 803⟶830 nm) detection. ICG is applied subcutaneously adjacent to the penile cancer or residual stump of penis or suprapubic region (in a history of total penectomy: 5 cases). E dose of ICG is 2.5 (5) mg diluted in 1 ml and can be applied preoperatively even in the suprapubic region in men with a history of total penectomy, with an unexplainable failure of ICG marking in 16.7%. Lymph node metastasis is the single most important prognostic factor determining survival in men with penile cancer. An integral part of the management of penile cancer is the detection of occult metastases to the inguinal lymph nodes (ILNs). Currently available noninvasive staging techniques still lack sufficient accuracy to reliably stage the nodal status

Methods
Results
Conclusion