This paper presents the performance characteristics of two induction motors of the same parameters and ratings connected in parallel and fed by a single inverter. A nature observer is employed to estimate the rotor speeds and rotor uxes of both induction motors. It also estimates the load torques of both the motors by load torque adaptation. Under unbalanced load conditions, the speed difference between the two induction motors is reduced by considering the average and differential motor parameters and currents. Mean rotor ux is maintained constant by a rotor ux control scheme and the estimation of rotor angle is carried out by direct vector control technique. The prototype experimental setup is made for validating the proposed method and the experimental results are demonstrated for various running conditions. The natural observer algorithm for speed and torque estimation is executed by TMS320F2812 DSP controller.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.