Abstract
We report a case of vascular assess challenge on a patient with severe kyphoscoliosis and joint contractures. Multiple internal jugular (IJ) central venous catheters (CVC) and a peripherally inserted central catheter (PICC) catheterization were attempted via ultrasound guidance and all resulted in malposition. The PICC attempt fortuitously pushed a malpositioned IJ into the correct position. Computed tomography (CT) demonstrated a narrow thoracic inlet with no definite venous stenoses. Therefore, severe chest wall deformity, a narrow thoracic inlet and inadequate positioning of the patient secondary to his contractures all contributed to the malposition of the PICC and CVCs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.