Abstract

Many tunnels are equipped with longitudinal ventilation systems to control smoke in the event of a fire. However, the influence of such ventilation on fire development and fire spread has rarely been considered. This paper presents the results of a study using a Bayesian methodology to estimate the effect of forced longitudinal ventilation on heat release rate (HRR) for fires in tunnels. The behaviour of car and heavy goods vehicle (HGV) fires with a range of forced ventilation velocities is investigated. Results are presented and the implications are discussed. It has been found that forced ventilation has a great enhancing effect on the HRR of HGV fires, but has little effect on the HRR of car fires.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.