Abstract

CT contrast media improves vessel visualization but can also confound calcification measurements. We evaluated variance in aorta attenuation from varied contrast-enhancement scans, and quantified expected plaque detection errors when thresholding for calcification. We measured aorta attenuation (AoHU) in central vessel regions from 10K abdominal CT scans and report AoHU relationships to contrast phase (non-contrast, arterial, venous, delayed), demographic variables (age, sex, weight), body location, and scan slice thickness. We also report expected plaque segmentation false-negative errors (plaque pixels misidentified as non-plaque pixels) and false-positive errors (vessel pixels falsely identified as plaque), comparing a uniform thresholding approach and a dynamic approach based on local mean/SD aorta attenuation. Females had higher AoHU than males in contrast-enhanced scans by 65/22/20 HU for arterial/venous/delayed phases (p < 0.001) but not in non-contrast scans (p > 0.05). Weight was negatively correlated with AoHU by 2.3HU/10kg but other predictors explained only small portions of intra-cohort variance (R2 < 0.1 in contrast-enhanced scans). Average AoHU differed by contrast phase, but considerable overlap was seen between distributions. Increasing uniform plaque thresholds from 130HU to 200HU/300HU/400HU produces respective false-negative plaque content losses of 35%/60%/75% from all scans with corresponding false-positive errors in arterial-phase scans of 95%/60%/15%. Dynamic segmentation at 3SD above mean AoHU reduces false-positive errors to 0.13% and false-negative errors to 8%, 25%, and 70% in delayed, venous, and arterial scans, respectively. CT contrast produces heterogeneous aortic enhancements not readily determined by demographic or scan protocol factors. Uniform CT thresholds for calcified plaques incur high rates of pixel classification errors in contrast-enhanced scans which can be minimized using dynamic thresholds based on local aorta attenuation. Care should be taken to address these errors and sex-based biases in baseline attenuation when designing automatic calcification detection algorithms intended for broad use in contrast-enhanced CTs.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call