Abstract

A study of the possibility of optimizing the efficiency of a catalytic palladium layer demonstrated that the minimum palladium adsorption providing a sufficient catalytic activity of the surface is Γmin = 3.178 × 10–6 mol m–2, which can be reached at a palladium dichloride concentration of 0.035 g L–1. It was shown that palladium(II) activates the surface of the insulator (is sorbed) from a true, rather than a colloid solution.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.