Abstract

Assess weight variations in Brazilian users of the 20 microg/day levonorgestrel-releasing intrauterine system (LNG-IUS, Mirena) for comparison with a cohort of users of the TCu 380A intrauterine device (IUD) and a cohort of users of the injectable contraceptive, depot-medroxyprogesterone acetate (DMPA) over a period of five years. A total of 163 users of the LNG-IUS, who had the device inserted in 1998, were admitted to the study. At the time of enrollment, each woman was matched by weight (+/- 1 kg) and age (+/- 1 year) to a woman using a TCu 380A IUD and to another woman using DMPA. All women were followed up for a period of five years. Each year weight was measured and the body mass index (BMI, kg/m2) was calculated. Age of the LNG-IUS users was 27.0 +/- 6.7 years (mean +/- SD), while age of the copper IUD users was 28.0 +/- 6.6 years and that of DMPA users was 26.9 +/- 6.5 years. Weight recorded at the onset of the study was 62.9 +/- 0.8 kg, 62.8 +/- 0.8 kg, and 62.5 +/- 0.9 kg (Mean +/- SD) for users of the LNG-IUS, the copper IUD, and DMPA, respectively. The BMI of women was initially 25.0 (+/- 0.3), 26.4 (+/- 0.3), and 25.5 (+/- 0.4), (Mean +/- SD), for users of the LNG-IUS, copper IUD, and DMPA, respectively. Weight increases of 3.1 kg, 4.9 kg and 8.2 kg were observed at the end of the fifth year among users of the LNG-IUS, copper IUD, and DMPA, respectively (p = 0.009). Increase of the BMI was also observed among all groups (final BMI was 26.3 +/- 0.7, 28.5 +/- 0.8 and 28.7 +/- 1.3 for users of the LNG-IUS, copper IUD and DMPA, respectively). Multivariate analysis showed that there was a significant association between weight increase and length of use of the contraceptive method and of the DMPA. The use of a LNG-IUS during five years caused no significant weight increase and the difference in weight was of the same magnitude as that of copper IUD users.

Highlights

  • Assess weight variations in Brazilian users of the 20 μg/ day levonorgestrel-releasing intrauterine system (LNG-IUS, Mirena®) for comparison with a cohort of users of the TCu 380A intrauterine device (IUD) and a cohort of users of the injectable contraceptive, depotmedroxyprogesterone acetate (DMPA) over a period of five years

  • Weight recorded at the onset of the study was 62.9 ± 0.8 kg, 62.8 ± 0.8 kg, and 62.5 ± 0.9 kg (Mean ± SD) for users of the LNG-IUS, the copper IUD, and DMPA, respectively

  • Weight increases of 3.1 kg, 4.9kg and 8.2kg were observed at the end of the fifth year among users of the LNG-IUS, copper IUD, and DMPA, respectively (p = 0.009)

Read more

Summary

Análise estatística

O tamanho amostral foi baseado em uma amostra piloto por meio do levantamento aleatório de 12 prontuários de mulheres usuárias de SIU-LNG. A coorte das mulheres usuárias de DIU Tcu foi conseguida por meio de um banco de dados preexistente e já publicado pelo pareamento da idade e do peso com as usuárias de SIU-LNG. Já o IMC no início do estudo foi de 25,0 ± 0,3 kg/m2, 26,4 ± 0,3 kg/m2 e 25,5 ± 0,4 kg/m2 para as usuárias de SIU-LNG, DIU Tcu e AMP-D, respectivamente. Entre as usuárias de DIU Tcu o aumento de peso de 4,9 kg ao longo dos cinco anos, que não foi significativo quando comparado com as usuárias de SIU-LNG (p=0,561). Tabela 1 – Médias do peso e IMC em usuárias de sistema intra-uterino liberador de levonorgestrel (SIU-LNG) e dispositivo intra-uterino de cobre (DIU Tcu) ao longo dos anos. Tabela 3 – Análise de variância multivariada para os métodos SIU-LNG e DIU Tcu em três tempos

Fonte de variação MAC Tempo MAC vs tempo