Abstract

The clinical standard for measuring corneal thickness is ultrasound pachymetry that assumes a constant speed of sound. The purpose of this study was to examine the variance of speed of sound and its relationship with acoustic impedance in healthy eyes of canines with a large age span. Corneal speed of sound and acoustic impedance were measured in 34 canine eyes at room temperature (21 ± 1°C). The mean speed of sound was 1577 ± 10 m/s ranging from 1553 to 1594 m/s. There was a strong correlation between speed of sound and acoustic impedance (R = 0.84, p < 0.001). Corneal speed of sound had a small variance in healthy canines over 1-year-old, but was significantly lower in younger canines suggesting an age effect. The strong correlation between corneal speed of sound and acoustic impedance may offer a potential means to noninvasively detect abnormal speed of sound for more accurate corneal thickness estimation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.