Abstract

The variable property solution for the natural convection in air-filled horizontal concentric annuli is obtained by using the variable property-based lattice Boltzmann flux solver. The effect of temperature difference ratio is discussed under the condition that the Ra and Pr numbers are 5×104 and 0.71, respectively. In the large-gap annulus, only one pair of counter-rotating eddies is formed, and the equivalent conductivity increases with temperature difference ratio. In the moderate-gap annulus, the flow patterns depend on temperature difference ratio, and the equivalent conductivity sometimes has a notable decrease as the eddy number changes. These demonstrate that temperature difference ratio should be considered as an important parameter in the study about flow instability behaviors and heat transfer characteristics under non-Boussinesq conditions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.