Abstract
Hysteresis current controllers having fixed bands are used in inverters of high-performance AC drives. The switching frequency of such controllers varies over the fundamental period of the modulating signal. The maximum switching frequency (MSF) of these controllers is high. To limit the MSF within the limit of inverter switches, fixed carrier lockouts are usually incorporated. The incorporation of carrier lockouts causes current distortion, and load currents do not confine within the predetermined band. In this paper, two new controllers are proposed. One is a mixed-mode controller of sinusoidal band added to a fixed band, and the other is an equidistant-band current controller, performances of the proposed controllers are compared with the performances of the conventional fixed-band and sinusoidal-band controllers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.