Abstract

Many studies have demonstrated that the optic nerve sheath diameter (ONSD) is a good indicator of intracranial pressure (ICP). There are uncertainties regarding the optimal ONSD threshold, considering age and sex differences in the healthy population, and these differences could lead to uncertainties in evaluation of ONSD in pathological conditions.The aim of this prospective observational study was to investigate if age and sex could influence ONSD in a cohort of healthy Italian volunteers recruited during preanesthetic assessment for low-risk surgical procedures.The population was stratified for sex (males versus females) and for age (18-44years, 45-64years, and ≥65years). The axial and longitudinal ONSD diameters were measured by two trained investigators.A significant difference in ONSD between males and females was found (median 4.2 (interquartile range 3.9-4.6) versus 4.1 (interquartile range 3.6-4.2) mm, P=0.01), and a positive correlation between ONSD and age was found (R=0.50, P<0.0001).It was concluded that ONSD increases with age and is significantly larger in the healthy male population. These discrepancies should be taken into consideration when ONSD measurement is performed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.