Abstract

The purpose of this study was to examine the effects of different contraction times and delay times prior to a positioning task. While blindfolded, each of 25 subjects learned to produce elbow-extension movements to a short and a long target using a kinesthesiometer. The subject then produced 30 trials without feedback to each target. These control trials were preceded by a foreperiod of 0-, 3-, or 6-sec. delay. The 60 experimental trials were identical to control trials except the subject isometrically contracted elbow extensor muscles for 3 or 6 sec. prior to each trial. Following each isometric contraction the subject delayed movement for 0, 3, or 6 sec. The 3-sec. and 6-sec. prepositioning contractions produced greater undershooting and variability than no prepositioning contractions, and the 0-sec. delay produced less constant error than either the 3- or 6-sec. delay. It was concluded that following isometric contraction, undershooting a target occurred and this effect did not dissipate within a 6-sec. period.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.