Abstract
ObjectiveDelineation of treatment volumes is a major source of uncertainties in radiotherapy (RT). This is also true for rectal cancer patients undergoing neoadjuvant RT, with a potential impact on treatment quality. We investigated the role of the digital platform Anatom-e (Anatom-e Information Sytems Ltd., Houston, Texas) in increasing the compliance to follow a specific treatment protocol in a multicentric setting. Materials and methodsTwo clinical cases of locally advanced rectal cancer were chosen. Participants were instructed to follow the 2009 Radiation Therapy Oncology Group consensus atlas and asked to manually segment clinical target volumes (CTVs), for both patient 1 and 2, on day 1 with and without the use of Anatom-e. After one week (day 2), the same radiation oncologist contoured again, with and without Anatom-e, the same CT series. Intraobserver (Intra-OV) and interobserver (Inter-OV) variability were evaluated with the Dice similarity coefficient (DSC), the Hausdorff distance (HD) and mean distance to agreement (MDA). ResultsFor clinical case 1, no significant difference was found for Intra-OV and Inter-OV. For clinical case 2, no significant difference was found for Intra-OV but a statistically significant difference was found for Inter-OV in DSC when using or not the platform. Mean DCS was 0.65 (SD: ±0.64; range: 0.58–0.79) for day 1 vs reference volume without Anatom-e and 0.72 (SD: ±0.39; range: 0.67–0.77) (p = 0.03) with it. Mean MDA was lower with Anatom-e (3.61; SD: ±1.33; range: 2.85–4.78) than without (4.14; SD: ±2.97; range: 2.18–5.21), with no statistical significance (p = 0.21) The use of Anatom-e decreased the SD from 2.97 to 1.33. Mean HD was lower with Anatom-e (26.06; SD: ±2.05; range: 24.08–32.62), with no statistical significance (p = 0.14) compared to that without (31.39; SD: ±1.31; range: 26.14–48.72). ConclusionsThe use of Anatom-e decreased the Inter-OV in the CTV delineation process for locally advanced rectal cancer with complex disease presentation planned for neoadjuvant RT. This system may be potentially helpful in increasing the compliance to follow shared guidelines and protocols.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.