Abstract
Transepidermal water loss (TEWL) has been suggested to be a measure which can be used to identify subjects at risk for the development of contact dermatitis. Transepidermal water loss is high when the barrier function of the skin is impaired. It is assumed that subjects with a high TEWL have skin which is more permeable to substances causing contact dermatitis. The inter-individual and intra-individual variability of simultaneous TEWL measurements and TEWL measurements over a period of three weeks were estimated in healthy individuals. The intra-individual coefficient of variation (CV) of simultaneous measurements was 13.5%. The intra-individual coefficient of variation of the measurements on consecutive days was somewhat higher (15.1%). The intra-individual coefficients of variation were low compared to the inter-individual coefficients of variation. The results indicate that transepidermal water loss is a stable personal characteristic, which can be studied as a risk factor in epidemiologic studies on contact dermatitis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Archives of Occupational and Environmental Health
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.