Abstract
Objectives. This study was designed to assess the most accurate and reproducible methods to quantitate mitral regurgitation by color flow trarasthoracic and transesophageal echocardiography.Background. Quantitative measurements of mitral regurgitant jets have resulted in an intraobserver and interobserver variability of up to 20%. Few data are available evaluating the various techniques by which mitral regurgitant jets are quantitated.Methods. Forty patients who underwent cardiac catheterization and both transesophageal and transthoracic echocardiography within 1 week were studied. Two boundaries of the color regurgitant jet area were identified and quantitated: 1) the central aliased core of the regurgitant jet with the mosaic pattern excluding any swirling low velocity flow; and 2) the largest definable area of the regurgitant flow, including low velocity flow considered to be part of the regurgitant jet.Results. The total regurgitant areas obtained by transthoracic and transesophageal studies did not differ (5.7 ± 4.6 vs. 5.7 ± 3.7 cm2; p = NS). However, the transesophageal mosaics were significantly larger than those obtained by transthoracic echocardiography (3.6 ± 3.1 vs. 2.8 ± 3.4 cm2; p < 0.01). In transthoracic studies observer variability was higher when the mosaic aspect of the regurgitant jet rather than the total regurgitant area was measured (24 ± 20 vs. 16 ± 11%; p < 0.05). In contrast, in transesophageal studies variability was lower when the mosaic area rather than the total regurgitant area was measured (11 ± 12% vs. 18 ± 18%; p < 0.05). The best correlations with left ventriculography were obtained by using the absolute tolal regurgitant area (r = 0.72) for transthoracic studies and the mosaic area of the jets (r = 0.87) for transesophageal studies.Conclusions. Doppler color flow jet areas correlate closely with angiographic results in the evaluation of mitral regurgitation. The total regurgitant area (including the surrounding swirling flow) in transthoracic studies and the aliased core of the regurgitant jet (mosaic) in transesophageal studies appear to be the most accurate and reproducible measurements for evaluating mitral regurgitation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.