Abstract
The vapour flow pattern of a free-burning arc of 20 mm length is studied varying the cathode and anode diameters independently from 5 to 22 mm. Roughly speaking, there are two flow patterns which depend on the electrode arrangement. One is a bidirectional flow pattern and the other a unidirectional flow pattern. In both cases, outward flow are always observed without any indication of the air entrainment. A rough estimation shows that the radiation loss is more than 84% of the total energy loss in the vapour dominant arc generated in the present condition.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.