Abstract
The vapor pressure of HFE 7100 was measured from (306 to 431) K for pressures from (36 to 1180) kPa using a Burnett apparatus. The temperature measurement uncertainty was estimated to be ± 5 mK, and the pressure uncertainty was estimated to be ± 300 Pa. A Wagner-type equation was used for the vapor pressure of HFE 7100 based on the experimental data. This equation contains five coefficients and correlates the measured vapor pressures within 0.11 %.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.