A high-temperature technique was developed for vapor pressure determination of solid and liquid γ-La2S3 (we called it the boiling point technique). Melting temperatures and total vapor pressures were measured for incongruently vaporizing γ-La2S3 at 1853–2210 K and 0.3–3.0 atm pressures. Having compared the slopes of the log p(S2) versus 1/T plots measured by various techniques, we recommend the equation log p(S2) [atm] = (6.31 ± 0.15) − (12720±310)T −1 for T = 1021–2013 K as the most reliable for practical use.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.