Abstract

BackgroundIn this study, we combined ultrasound and Doppler parameters to conclude the most accurate and applicable method for fetal lung maturity assessment. Thepurpose is to reduce risk of neonatal respiratory distress by assessment of fetal lung maturity through ultrasound and Doppler instead of amniocentesis.ResultsA total of 120 women were included. The ultrasound examination was performed at a gestational age ranging between 30 and 37 weeks and delivery occurred within 72 h from ultrasound. After birth, 19 fetuses were diagnosed with RDS.The ultrasound parameters assessed for fetal lung maturity showed varying sensitivity and specificity but presence of proximal tibial epiphyses showed the highest sensitivity (91%) and specificity (95%) followed by the presence of distal femoral epiphyses with 90% sensitivity and 84% specificity. The placental grade III maturity showed a sensitivity of 81% and 74% specificity followed by the presence of the amniotic fluid free-floating particles with an 83% sensitivity and 63% specificity, while echogenic fetal thalamus showed 77% and 79% for sensitivity and specificity, respectively, for prediction of fetal lung maturity. By using the fetal biometry, we could report that a BPD between 82.8 and 93.5 mm, AC between 295 and 322 mm, and FL (62.7-72.1 mm) correlated with mature fetal lungs. Regarding Doppler indices, increased resistive index of umbilical artery > 0.69 and of pulmonary artery > 0.78 correlated with neonatal RDS while fetuses with UtA RI values between 0.43 and 0.66 noticed in RDS vs (0.42-0.57) in the non-RDS. MCA RI values are also higher in RDS 0.77–0.88 vs 0.74–0.79 in non-RDS.On the other hand, analysis of colon grading and fetal lung echogenicity in relation to liver showed no significant value in the assessment of fetal lung maturity.ConclusionUltrasound and Doppler showed good predictive value and accuracy and is considered a valuable non-invasive procedure in assessment of fetal lung maturity. However, no single parameter alone could show a definitive sign

Highlights

  • In this study, we combined ultrasound and Doppler parameters to conclude the most accurate and applicable method for fetal lung maturity assessment

  • Multiple studies discussed the utility of ultrasound in assessing the fetal lung maturity; ultrasound parameters used were bi-parietal diameter, femur length, epiphyseal centers of the lower limb, placental grading, colon grading, and free-floating particles in the amniotic fluid [3,4,5]

  • A total of 200 women were examined in this prospective cohort study, 80 were excluded either due to delivery after 37 weeks of gestation or more than 72 h after sonography was carried out, administration of antenatal corticosteroids, inability to obtain proper Doppler waveforms, or inability of follow up of the neonatal outcome

Read more

Summary

Introduction

We combined ultrasound and Doppler parameters to conclude the most accurate and applicable method for fetal lung maturity assessment. The purpose is to reduce risk of neonatal respiratory distress by assessment of fetal lung maturity through ultrasound and Doppler instead of amniocentesis. Neonatal respiratory distress syndrome (RDS) remains a major cause of mortality and morbidity in the newly born infants due to immaturity of their lungs. It occurs mainly in newborns who are delivered pre-maturely, and it is associated reversely with gestational age at birth [1]. Multiple studies discussed the utility of ultrasound in assessing the fetal lung maturity; ultrasound parameters used were bi-parietal diameter, femur length, epiphyseal centers of the lower limb, placental grading, colon grading, and free-floating particles in the amniotic fluid [3,4,5]

Methods
Results
Discussion
Conclusion