Abstract
Thallium-201 chloride single photon emission computed tomography (201Tl SPECT) has been proposed as a diagnostic tool in the assessment of patients with brain tumors. We performed SPECT scans coupled with magnetic resonance imaging (MRI) in children with brain tumors to determine the sensitivity and potential value of SPECT in neuro-oncology. Each patient was injected with 2.5-3.0 mCi of thallium chloride, followed by technetium-99m HMPAO (5-15 mCi) to assess cerebral perfusion. 201Tl uptake was imaged with triple-headed SPECT in 20/24 (83%) histologically and anatomically diverse neoplasms with MRI-measurable residual disease, including 13/16 (80%) posterior fossa tumors. 201Tl SPECT demonstrated uptake in tumors with MRI volumes ranging from 0.03 to 60 cm3. 201Tl SPECT imaging was not correlated with the following MRI features: gadolinium enhancement, necrosis, exophytic, unicentric and multicentric. 201Tl uptake was not detectable in patients with tumors of maldevelopmental origin or radionecrosis. It is suggested that 201Tl SPECT is an important imaging adjunct in the assessment of children with brain tumors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.