Abstract

Mild asthma is often characterized by normal spirometric values and a negative bronchodilation test (BDT), which makes accurate diagnosis challenging. The aim of our study was to evaluate the diagnostic accuracy of fractional exhaled nitric oxide (FeNO) in mild asthma. In adults with symptoms suggestive of asthma and normal spirometry values, BDT, FeNO, BPT and skin prick testing were performed. Patients with positive BPT started inhaled corticosteroid (ICS) therapy. Those with positive response to ICS were considered asthmatics. There were 142 asthmatics and 140 non-asthmatics. No significant difference was found in BDT between the groups, p = 0.233. Median FeNO levels were significantly higher in the asthma group (49.5 ppb) than in the non-asthma group (23 ppb), p < 0.001. BPT was positive in 145 (51.42%) and negative in 137 (48.58%) patients. Positive response to ICS treatment was recorded in 142/145 (97.9%) patients. In diagnosing asthma, FeNO ≥ 25 ppb had a sensitivity of 75.4% and specificity of 47.9%. FeNO has insufficient sensitivity and specificity in mild asthma and the application of BPT is often necessary to establish an accurate diagnosis.