Abstract

Objective To explore the value of elastography strain ratio(SR)combined with breast ultrasound imaging reporting and data system(BI-RADS-US)in the differential diagnosis of breast nodules.Methods A total of 471 breast nodules(from 471 patients)were reclassified by SR combined with BI-RADS-US.With the pathology results as gold standard,the area under the receiver operating characteristic(ROC)curve(AUC)was employed to evaluate the diagnostic performance,and the sensitivity,specificity,and accuracy were compared between the combined method and BI-RADS-US.Results Among the 471 breast nodules,180 nodules were benign and 291 were malignant.The AUC of the combined method was statistically significantly higher than that of BI-RADS-US(0.798 vs. 0.730;Z= 2.583, P= 0.010).SR,BI-RADS-US,and the combined method for diagnosing breast nodules had the sensitivity of 86.6%,99.0%,and 96.6%,the specificity of 67.2%,47.2%,and 63.3%,and the accuracy of 79.2%,79.2%,and 83.9%,respectively.The combined method increased the specificity from 47.2%(BI-RADS-US)to 63.3%(χ 2=14.25,P < 0.001),and downgraded 57.5%(42/73)benign nodules of BI-RADS category 4A to category 3.Conclusions SR combined with BI-RADS-US can improve the diagnostic performance for breast nodules.Especially,it can improve the specificity,avoiding unnecessary biopsy of breast nodules.