Abstract

Background The fractional flow reserve (FFR) derived from coronary computed tomography (CT) angiography (FFRCT) is a variable tool for coronary disease diagnosis that non-invasively provides the value of FFR. It can add physiological information tocoronary CT angiography (CCTA) and reduce unnecessary invasive coronary angiography (CAG). However, it cannot be analyzed in some cases, which is also called "non-measurability." While FFRCT has become globally widespread, the current data on non-measurability are lacking. This study aimed to determine the rate of non-measurability and identify predictors thereof in routine clinical settings to explore potential approaches to reduce the non-measurability rate. Methods and results This retrospective observational single-center studyincluded consecutive patients who underwent FFRCTanalysis in Japan. The mean age of the overall population was 71.3 ± 10.6, and an FFRCTof ≤0.8 was seen in 47.6% of patients with a measurable FFRCT. Of the 307 enrolled patients, FFRCT analysis was not feasible in 21 cases (6.8%). Heart rate (HR) at a CT scan and coronary calcium scores (CCS) were significantly higher in patients with non-measurability than those in patients whose FFRCT was appropriately analyzed (HR: 69.6±8.9 bpm vs. 61.0±11.1 bpm; p < 0.01; CCS; 931.2 (290.8, 1451.3) vs. 322.9 (100.7, 850.0); p < 0.01). Multiplelogisticregression showed that HR was an independent predictor for non-measurability (odds ratio: 1.05; 95% confidential interval: 1.02, 1.09; p < 0.01)). Based on the receiver operating characteristic curve analysis, the optimal cut-off value of HR and CCS was 63 bpm (specificity: 67.1%; sensitivity: 76.2%) and 729.2 (specificity: 71.3%; sensitivity: 66.7%). In addition, the combination of two features (HR > 63 bpm and CCS > 729.2) showed a high negative predictive value (99.3%) for FFRCT non-measurability. Conclusions In this study, the rate of FFRCTnon-measurability was 6.8%. Higher HR at a CT scan and CCS were significantly associated with non-measurability, and in cases with both HR and CCS below a specified threshold, the likelihood of ruling out non-measurability could be significantly high. Our findings suggest that reducing the HR to ideally under 63 bpm at the time of the CT scan significantly ensures feasibility. Further study on large-scale cohorts is warranted.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.