Abstract
ABSTRACT This study assessed the validity of the Entralpi force plate in the assessment of finger flexor performance in rock climbers. In addition to a static force evaluation, peak force, peak impulse, and total impulse were measured during 30 all-out performance trials by 15 participants, in which force during the trials was recorded simultaneously by the Entralpi and a Pasco force plate. Agreement between devices was assessed by a variety of statistical analyses, including intraclass correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman analyses. The static force evaluation showed a mean relative error of 0.41% and excellent day-to-day reliability (ICC = 1; CV = 0.03%). Peak force, peak impulse, and total impulse from the performance trials demonstrated strong agreement (ICC ≥ 0.991, CV ≤ 1.9%, Bland-Altman mean bias ≤ 0.5%). These results illustrate that the Entralpi force plate provides accurate and reliable data for rock climbing related tasks at an affordable cost.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.