Abstract

The objective of this cross-sectional study was to estimate the validity of laboratory culture, Petrifilm and Tri-Plate on-farm culture systems, and luminometry to correctly identify IMI at dry-off in dairy cows, considering all tests as imperfect. From September 2020 until December 2021, we collected composite milk samples from cows before dry-off and divided them into 4 aliquots for the luminometry test, the Petrifilm (aerobic count), the Tri-Plate, and the laboratory culture. While we assessed multiple thresholds of relative light units (RLU) for the luminometry, we used thresholds of ≥100 cfu/mL for the laboratory culture, ≥ 50 cfu/mL for the Petrifilm, and ≥1 cfu for the Tri-Plate. We fitted Bayesian latent class analysis (LCA) models to estimate the sensitivity (Se) and specificity (Sp) for each test to identify IMI, with 95% credibility interval (BCI). Using different prevalence measures (0.30, 0.50, and 0.70), we calculated the predictive values (PV) and misclassification cost terms (MCT) at different false-negative to false-positive ratios (FN:FP). A total of 333 cows were enrolled in the study from one commercial Holstein herd. The validity of the luminometry was poor for all thresholds, with Se of 0.51 (95% BCI = 0.43-0.59) and Sp of 0.38 (95% BCI = 0.26-0.50) when using a threshold of ≥150 RLU. The laboratory culture had Se of 0.93 (95% BCI = 0.85-0.98) and Sp of 0.69 (95% BCI = 0.49-0.89), the Petrifilm had Se of 0.91 (95% BCI = 0.80-0.98) and Sp of 0.71 (95% BCI = 0.51-0.90), and the Tri-Plate had Se of 0.65 (95% BCI = 0.53-0.82) and Sp of 0.85 (95% BCI = 0.66-0.97). Bacteriological tests had good PVs, with comparable positive PV for all 3 tests, but lower negative PV for the Tri-Plate compared with the laboratory culture and the Petrifilm. For a prevalence of IMI of 0.30, all 3 tests had similar MCT, but for prevalence of 0.50 and 0.70, the Tri-Plate had higher MCT in scenarios where leaving a cow with IMI untreated is considered to have greater detrimental impacts than treating a healthy cow (i.e., FN:FP of 3:1). Our results showed that the bacteriological tests have adequate validity to diagnose IMI at dry-off, but the luminometry does not. We concluded that, while luminometry is not useful to identify IMI at dry-off, the Petrifilm and Tri-Plate tests performed similarly to the laboratory culture, depending on the prevalence and the importance of the FP and FN results.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call