Abstract

General and particularly sport-specific testing is an integral aspect of performance optimization in artistic gymnastics. In artistic gymnastics, however, only non-specific field tests have been used to assess endurance performance (e.g., Multistage Shuttle Run Test; Cooper's Test). This study aimed to examine the validity of a new sport-specific endurance test in artistic gymnastics. Fourteen elite-level gymnasts (i.e., eight males and six females) participated in this study. The newly developed artistic gymnastics-specific endurance test (AGSET) was conducted on two different occasions seven days apart to determine its reliability. To assess the concurrent validity of AGSET, participants performed the multistage shuttle run test (MSRT). Maximum oxygen uptake (VO2max) and respiratory exchange ratio (RER) were directly assessed using a portable gas analyzer system during both protocols. Additionally, the total time maintained (TTM) during the AGSET, maximum heart rate (HRmax), maximal aerobic speed (MAS), and blood lactate concentration (BLa) during the two protocols were collected. The main findings indicated that all variables derived from the AGSET (i.e., VO2max, MAS, HRmax, BLa, and RER) displayed very good relative (all intraclass correlation coefficients [ICC] > 0.90) and absolute (all typical errors of measurement [TEM] < 5%) reliability. Further, results showed that the ability of the AGSET to detect small changes in VO2max, MAS, BLa, and RER was good (smallest worthwhile change [SWC0.2] > TEM), except HRmax (SWC0.2 < TEM). Additionally, results showed a nearly perfect association between the VO2max values derived from the AGSET and MSRT (r = 0.985; coefficient of determination [R²] = 97%) with no statistically significant differences (p>0.05). The mean (bias) ± 95% limits of agreement between the two protocols were 0.28 ± 0.55 mlminkg-1. AGSET seems to present very good reliability and concurrent validity for assessing endurance performance in elite artistic gymnastics. In addition, the newly developed protocol presents a good ability to detect small changes in performance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.