ABSTRACTCountermovement jump (CMJ) height is an important parameter in physical performance. This study compared CMJ height measured using ChronoJump contact mat (CJ) and Myotest accelerometer (MT) systems with a force platform (FP). Thirty recreationally active adults (32.1 ± 10.4 years, 75.9 ± 12.0 kg, 173.2 ± 6.3 cm) completed a CMJ protocol where height was simultaneously recorded using the three systems. CJ and MT measures were strongly and significant correlated (r = 0.65, 0.66, respectively; p < 0.05) with FP. CJ-derived measures were not significantly different to FP measures (p > 0.05), yet MT-derived measures were significantly different from those obtained using the FP (p < 0.05). Systematic bias was observed between FP and the CJ and between FP and MT. This study demonstrates the validity of CJ and MT systems for the assessment of CMJ height. Systematic bias and between-device differences in measurement should be considered when interpreting and comparing data from these devices.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.