This study aimed to determine the intra- and inter-device accuracy and reliability of wearable athletic tracking devices, under controlled laboratory conditions. A total of nineteen portable accelerometers (Catapult OptimEye S5) were mounted to an aluminum bracket, bolted directly to an Unholtz Dickie 20K electrodynamic shaker table, and subjected to a series of oscillations in each of three orthogonal directions (front-back, side to side, and up-down), at four levels of peak acceleration (0.1g, 0.5g, 1.0g, and 3.0g), each repeated five times resulting in a total of 60 tests per unit, for a total of 1140 records. Data from each accelerometer was recorded at a sampling frequency of 100Hz. Peak accelerations recorded by the devices, Catapult PlayerLoad™, and calculated player load (using Catapult’s Cartesian formula) were used for the analysis. The devices demonstrated excellent intradevice reliability and mixed interdevice reliability. Differences were found between devices for mean peak accelerations and PlayerLoad™ for each direction and level of acceleration. Interdevice effect sizes ranged from a mean of 0.54 (95% CI: 0.34–0.74) (small) to 1.20 (95% CI: 1.08–1.30) (large) and ICCs ranged from 0.77 (95% CI: 0.62–0.89) (very large) to 1.0 (95% CI: 0.99–1.0) (nearly perfect) depending upon the magnitude and direction of the applied motion. When compared to the player load determined using the Cartesian formula, the Catapult reported PlayerLoad™ was consistently lower by approximately 15%. These results emphasize the need for industry wide standards in reporting validity, reliability and the magnitude of measurement errors. It is recommended that device reliability and accuracy are periodically quantified.
Highlights
Wearable devices designed to measure performance metrics have become ubiquitous in the athletics community
Differences were found between devices for mean peak accelerations, and PlayerLoadTM for each direction and level of applied external loading (Figs 2–4)
Differences were found between Catapult peak accelerations and the PCB reference accelerometer peak accelerations for each direction and level of applied acceleration (Fig 4), where effect sizes ranged from a mean of 0.36 to 1.15 (Table 5)
Summary
Wearable devices designed to measure performance metrics have become ubiquitous in the athletics community. The use of GPS-based devices presents certain limitations: a) they cannot be used indoors [3], and b) questionable validity and reliability to accurately assess short, high-intensity movements due to its low sampling rate (1–10 Hz) [3]. Another common approach to player tracking is the use of multi-camera systems that use image-processing techniques (i.e., motion capture) to determine the position of an athlete within a particular physical space. Advances in computer processing (e.g., software algorithms and hardware) continue to make this approach more and more desirable, but the currently available systems suffer from two limitations: a) their use is generally confined to indoor sports because tracking accuracy depends upon the size of the physical space, and b) these systems require post-event processing to accurately determine player position
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.