Abstract

The four-meter gait speed (4MGS) is a recommended physical performance test in older adults but is challenging to implement clinically. We developed a smartphone application (App) with a four-meter ribbon for remote 4MGS testing at home. This study aimed to assess the validity and reliability of this smartphone App-based assessment of the home 4MGS. We assessed the validity of the smartphone App by comparing it against a gold standard video assessment of the 4MGS conducted by study staff visiting community-dwelling older adults and against the stopwatch-based measurement. Moreover, we assessed the test-retest reliability in two supervised sessions and three additional sessions performed by the participants independently, without staff supervision. The 4MGS measured by the smartphone App was highly correlated with video-based 4MGS (r = 0.94), with minimal differences (mean = 0.07 m/s, ± 1.96 SD = 0.12) across a range of gait speeds. The test-retest reliability for the smartphone App 4MGS was high (ICC values: 0.75 to 0.93). The home 4MGS in older adults can be measured accurately and reliably using a smartphone in the pants pocket and a four-meter strip of ribbon. Leveraging existing technology carried by a significant portion of the older adult population could overcome barriers in busy clinical settings for this well-established objective mobility test.