Abstract

DE-310 is a macromolecular carrier conjugate containing an anti-tumor camptothecin derivative, DX-8951, which is conjugated to a water-soluble polymer via a peptide spacer. Assay methods have been developed for the determination of a polymer-bonded DX-8951 conjugate, DX-8951, and Glycyl-DX-8951 (G-DX-8951) in mouse plasma. Free DX-8951 and Glycyl-DX-8951 were extracted from plasma by protein precipitation and analyzed by HPLC (Method I). Conjugated DX-8951 was extracted by protein precipitation and digested by using a thermolysin. The productive compound was analyzed by HPLC (Method II). The lower limits of quantitation of DX-8951, Glycyl-DX-8951, and Conjugated DX-8951 were 0.60, and 0.77 ng/ml and 3.45 μg/ml (as DX-8951 equivalent). These two methods showed satisfactory sensitivity, precision, accuracy, recovery, and selectivity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.