Abstract
Vitamin D and its adequate status are related to many aspects of human health; therefore, an appropriate tool is needed for the valid assessment of vitamin D status. The main contributor to vitamin D status is endogenous synthesis after cutaneous exposure to ultraviolet B light (UVB), but in the absence of UVB radiation, vitamin D intake becomes an important source of vitamin D. Various tools are available for vitamin D intake assessments, with the Food Frequency Questionnaire (FFQ) being among the fastest, cheapest, and most convenient; however, until now, these tools have not been adapted for the Slovenia (SI). To enable valid vitamin D intake estimation, we developed a simple one-page semi-quantitative FFQ (sqFFQ/SI) and tested its validity using a 5-day dietary record (DR) as a reference method. The reproducibility was tested with the second sqFFQ/SI (sqFFQ/SI2) 6 weeks after the first (sqFFQ/SI1). The validity and reproducibility of this method were tested on 54 participants using Bland–Altman plots, Spearman’s correlation, and Kappa analyses of tertiles. The mean daily vitamin D intake was 3.50 ± 1.91 μg according to the 5-day DR, and 2.99 ± 1.35 and 3.31 ± 1.67 μg according to the sqFFQ/SI1 and repeated sqFFQ/SI (sqFFQ/SI2), respectively. When analyzing for validity, the sqFFQ/SI1 was found to be significantly correlated (p < 0.05) with the 5-day DR, with an acceptable correlation coefficient of 0.268 and a Bland–Altman index of 3.7%. For reproducibility, the correlation between the sqFFQ/SI1 and sqFFQ/SI2 was highly significant (p < 0.001), with a good correlation coefficient of 0.689 and a Bland–Altman index of 3.7%. Kappa analyses of tertiles showed a poor validity and acceptable reproducibility. Overall, we observed a higher reproducibility than validity. Validation and reproducibility analyses demonstrated that the proposed sqFFQ/SI is acceptable and is, therefore, an appropriate tool for the effective assessment of habitual vitamin D intake on an individual level. With this consideration, this tool will be used in further population studies to assess vitamin D intake and for the development of a screening tool for the assessment of the risk for vitamin D deficiency, which will be used as a foundation for evidence-based policy-making decisions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.