Abstract

The AC loss tests on the first ITER Central Solenoid Module (CSM) have been modelled and compared to the test results. The model has been implemented in the 4 C code, a thermal-hydraulic modelling tool which includes the CSM winding pack and the cryogenic circuit of the test facility. Two modes of operation of the circuit have been analyzed: the nominal and the “isolation” mode, i.e., when the cryogenic circuit valves are operated to isolate the coil during the current dumps. The computed mass flow rate, pressure and coil outlet temperature at different locations have been compared with the measurements, showing a very good agreement in both modes of operation of the circuit. The validated model helped in the interpretation of the experimental results, such as the backflow at the coil inlet -which cannot be measured- or the non-monotonic outlet temperature evolution following the current dump. Furthermore, the code was used to qualify the isochoric method for the quantification of the deposited energy due to AC losses, as it was the only method applicable in case of current dumps from high current.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.