This study tested the concurrent and construct validity of smartphone accelerometry measurement of sit-to-stand (STS) performance in individuals aged 65-89 years. Normal and fast STS times were recorded by smartphone accelerometer, force plate, and video motion systems concurrently, and isokinetic knee extension power and STS whole-body power were obtained. Normal and fast speed STS times from a smartphone accelerometer agreed closely with force plate and motion system methods (mean difference = 0.04s). Normal and fast STS times were inversely related to isokinetic knee extension power (r = -.93, p < .001 and r = -.82, p < .001, respectively) and STS whole-body power (r = -.76, p < .001 and r = -.70, p < .001, respectively). The STS time obtained from a smartphone accelerometer was equivalent to the established, precise measures of STS time and was related to lower-extremity power, making it a potentially useful metric of lower-extremity function.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.