Abstract
Background and purposeDeveloping NTCP-models for cardiac complications after breast cancer (BC) radiotherapy requires cardiac dose-volume parameters for many patients. These can be obtained by using multi-atlas based automatic segmentation (MABAS) of cardiac structures in planning CT scans. We investigated the relevance of separate multi-atlases for deep inspiration breath hold (DIBH) and free breathing (FB) CT scans. Materials and methodsBC patients scanned in DIBH (n = 10) and in FB (n = 20) were selected to create separate multi-atlases consisting of expert panel delineations of the whole heart, atria and ventricles. The accuracy of atlas-generated contours was validated with expert delineations in independent datasets (n = 10 for DIBH and FB) and reported as Dice coefficients, contour distances and dose-volume differences in relation to interobserver variability of manual contours. Dependency of MABAS contouring accuracy on breathing technique was assessed by validation of a FB atlas in DIBH patients and vice versa (cross-validation). ResultsFor all structures the FB and DIBH atlases resulted in Dice coefficients with their respective reference contours ≥ 0.8 and average contour distances ≤ 2 mm smaller than slice thickness of (CTs). No significant differences were found for dose-volume parameters in volumes receiving relevant dose levels (WH, LV and RV). Accuracy of the DIBH atlas was at least similar to, and for the ventricles better than, the interobserver variation in manual delineation. Cross-validation between breathing techniques showed a reduced MABAS performance. ConclusionMulti-atlas accuracy was at least similar to interobserver delineation variation. Separate atlases for scans made in DIBH and FB could benefit atlas performance because accuracy depends on breathing technique.
Highlights
Background and purposeDeveloping Normal Tissue Complication Probability (NTCP)-models for cardiac complications after breast cancer (BC) radiotherapy requires cardiac dose-volume parameters for many patients
We investigated the relevance of separate multi-atlases for deep inspiration breath hold (DIBH) and free breathing (FB) CT scans
Materials and methods: BC patients scanned in DIBH (n = 10) and in FB (n = 20) were selected to create separate multi-atlases consisting of expert panel delineations of the whole heart, atria and ventricles
Summary
Developing NTCP-models for cardiac complications after breast cancer (BC) radiotherapy requires cardiac dose-volume parameters for many patients. These can be obtained by using multi-atlas based automatic segmentation (MABAS) of cardiac structures in planning CT scans. The accuracy of atlas-generated contours was validated with expert delineations in independent datasets (n = 10 for DIBH and FB) and reported as Dice coefficients, contour distances and dose-volume differences in relation to interobserver variability of manual contours. Dependency of MABAS contouring accuracy on breathing technique was assessed by validation of a FB atlas in DIBH patients and vice versa (crossvalidation). Separate atlases for scans made in DIBH and FB could benefit atlas performance because accuracy depends on breathing technique
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.