Abstract

The development of lightweight portable sensors and algorithms for the identification of gait events at steady-state running speeds can be translated into the real-world environment. However, the output of these algorithms needs to be validated. The purpose of this study was to validate the identification of running gait events using data from Inertial Measurement Units (IMUs) in a semi-uncontrolled environment. Fifteen healthy runners were recruited for this study, with varied running experience and age. Force-sensing insoles measured normal foot-shoe forces and provided a standard for identification of gait events. Three IMUs were mounted to the participant, two bilaterally on the dorsal aspect of the foot and one clipped to the back of each participant’s waistband, approximating their sacrum. The identification of gait events from the foot-mounted IMU was more accurate than from the sacral-mounted IMU. At running speeds <3.57 m s−1, the sacral-mounted IMU identified contact duration as well as the foot-mounted IMU. However, at speeds >3.57 m s−1, the sacral-mounted IMU overestimated foot contact duration. This study demonstrates that at controlled paces over level ground, we can identify gait events and measure contact time across a range of running skill levels.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call