Abstract

Despite gratifying immediate results, significant recoarctation at follow-up has been observed after balloon angioplasty of native aortic coarctation. Risk factors for such recurrences have been identified in one of our previous studies. In this study we examined the value of these risk factors in the prediction of recoarctation after balloon angioplasty. During a 6-year period ending in September 1993, 37 infants and children aged 2 days to 15 years underwent balloon angioplasty of native coarctation with resultant reduction in coarctation gradient from 45 ± 17 (mean ± SD) to 12 ± 9 mm Hg ( p < 0.001). On the basis of results of 4- to 48-month follow-up catheterization in 30 children, recoarctation developed in 8 (27%) children. The data from these patients were scrutinized to identify subjects that exhibited the previously determined risk factors, namely age <12 months, size of aortic isthmus less than two thirds the size of the ascending aorta, coarcted aortic segment <3.5 mm before angioplasty, and coarcted segment <6.0 mm after angioplasty. Then, thirty variables (Table I) were examined by logistic regression to identify factors responsible for recoarctation; the data from both study groups were combined for this analysis. The prevalence of recoarctation in each subgroup with a given number of risk factors is similar ( p < 0.1) to that observed in the initial study identifying the risk factors. In addition, logistic regression identified age ( p = 0.014), size of isthmus ( p = 0.006), preangioplasty coarcted segment ( p = 0.01), and postangioplasty coarcted segment ( p = 0.006) as risk factors. The younger the age, the narrower the aortic isthmus, and the smaller the coarcted segment (both before and after angioplasty), the greater the chance for recoarctation. In conclusion, the data from this study validate the reliability of previously identified risk factors in predicting recoarctation after balloon angioplasty of native coarctation. Identification of risk factors may help in selection of patients for balloon angioplasty.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.