Abstract

This paper presents the validation of RELAP5/MOD3.2 model of the VVER 440 for Nuclear Power Plant (NPP) in the analysis of the following transient: “Trip off one MCP”. This validation is a process that compares the analytical results obtained by RELAP5/MOD3.2 model of the VVER 440 with measurement transient data received from Kozloduy NPP Unit #4. The baseline input deck for VVER440 was developed at the Institute for Nuclear Research and Nuclear Energy for analyses of operational occurrences, abnormal events, and design basis scenarios. It will provide a significant analytical capability for the Bulgarian technical specialists located at the Kozloduy NPP. The criteria used in selecting transient are: importance to safety, availability and suitability of data followed by suitability for RELAP5 code validation. The comparison between the RELAP5 calculations and the test data indicates a good agreement. This validation was possible through the participation of leading specialists from Kozloduy NPP and with the support of the Argonne National Laboratory, under the International Nuclear Safety Program (INSP) of the United States Department of Energy.