Abstract
Mixed reality may offer an alternative for computer-assisted navigation in shoulder arthroplasty. The purpose of this study was to determine the accuracy and precision of mixed-reality guidance for the placement of the glenoid axis pin in cadaver specimens. This step is essential for accurate glenoid placement in total shoulder arthroplasty. Fourteen cadaveric shoulders underwent simulated shoulder replacement surgery by 7 experienced shoulder surgeons. The surgeons exposed the cadavers through a deltopectoral approach and then used mixed-reality surgical navigation to insert a guide pin in a preplanned position and trajectory in the glenoid. The mixed-reality system used the Microsoft Hololens 2 headset, navigation software, dedicated instruments with fiducial marker cubes, and a securing pin. Computed tomography scans obtained before and after the procedure were used to plan the surgeries and determine the difference between the planned and executed values for the entry point, version, and inclination. One specimen had to be discarded from the analysis because the guide pin was removed accidentally before obtaining the postprocedure computed tomography scan. Regarding the navigated entry point on the glenoid, the mean difference between planned and executed values was 1.7 ± 0.8 mm; this difference was 1.2 ± 0.6 mm in the superior-inferior direction and 0.9 ± 0.8 mm in the anterior-posterior direction. The maximum deviation from the entry point for all 13 specimens analyzed was 3.1 mm. Regarding version, the mean difference between planned and executed version values was 1.6° ± 1.2°, with a maximum deviation in version for all 13 specimens of 4.1°. Regarding inclination, the mean angular difference was 1.7° ± 1.5°, with a maximum deviation in inclination of 5°. The mixed-reality navigation system used in this study allowed surgeons to insert the glenoid guide pin on average within 2 mm from the planned entry point and within 2° of version and inclination. The navigated values did not exceed 3 mm or 5°, respectively, for any of the specimens analyzed. This approach may help surgeons more accurately place the definitive glenoid component.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.