Abstract
To validate the Manipal Bedside Swallowing Screening Test (MBSST) for assessing aspiration in individuals with tracheostomy using Video Fluoroscopic Swallow Study (VFSS). A total of 53 tracheostomized participants were screened for aspiration at bedside and VFSS across different consistencies. Penetration Aspiration Scale (PAS) was used to substantiate the severity of aspiration if present. The test demonstrated both high sensitivity (91%; 95% confidence interval = 70.8-98.9) and diagnostic accuracy (96%; 95% confidence interval = 87.0-99.5) for detecting aspiration in individuals with tracheostomy. The Manipal Bedside Swallowing Screening Test is an easy to administer tool that has sufficient sensitivity to detect aspiration in individuals with tracheostomy. The MBSST will be an easy to administer tool and will help in screening for aspiration at bedside without any instrumental examination.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Indian journal of otolaryngology and head and neck surgery : official publication of the Association of Otolaryngologists of India
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.