Abstract

We sought to determine whether mid-sagittal intracranial area (ICA) is a valid surrogate of intracranial volume (ICV) when using retrospective data with relatively thick (6-7 mm) sagittal slices. Data were retrospectively analyzed from 47 subjects who had two MRI scans taken at least nine months apart. Twenty-three subjects had manual segmentation of ICV on the T2-weighted sequence for comparison. Intraclass correlation coefficient (ICC) for intraobserver, interobserver, and intraobserver scan-rescan comparisons were 0.96, 0.97 and 0.95. Pearson correlation coefficients between ICV and ICA, averaging the cumulative 1, 2, 3, and 4 most midline slices, were 0.89, 0.94, 0.93, and 0.95. There was a significant marginal increase in explained variance of ICV by measuring two, rather than one, slices (P= 0.001). These data suggest that ICA, even measured without high-resolution imaging, is a reasonable substitute for ICV.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.