Abstract
MS23 is a vasodilator with unique dual action pharmacological profile to inhibit type 4 PDE and antagonize L-type calcium channels. We validated an analytical protocol for MS23 in rat plasma using high performance liquid chromatography (HPLC). A C18 column and a phosphate/acetonitrite buffer were used for chromatographic separation. UV detection was performed at 307 nm. The calibration curve for MS23 was linear in the range from 50 to 10,000 ng/ml. The limit of quantification (LOQ) was 50 ng/ml. The results demonstrate that the method has linearity (R = 0.9989), specificity, and acceptable precision/accuracy. This method is simple, economic, and sufficient for in vivo pharmacokinetic studies on the compound.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.